• JingGong Optical (Wenzhou International Trade SCM Co., Ltd.)
    Adrian, Optical Distributor
    Lucky to met with JingGong Optical team at MIDO in Milano, now all items we are selling are imported from them, excellent team and works.
  • JingGong Optical (Wenzhou International Trade SCM Co., Ltd.)
    Jane
    I tried JingGong auto refractor at Hong Kong optical fair, I decided to use their equipment for my second store, until now all my 10 shops over Albania are using JingGong Optical only, even for small parts they can give me great quality in a reasonable price.
  • JingGong Optical (Wenzhou International Trade SCM Co., Ltd.)
    Bob
    I tried more than 10 suppliers for our optical instruments business but JingGong is the best, they can provide the real professional answers to solve our problems, recommended supplier!
Contact Person : Jessica
Phone Number : 86-13506517907
WhatsApp : +8613506517907

Automatic Non-Contact Tonometer NCT-NT-800, Digital Intraocular Pressure (IOP) Measurement, Pachymetry Compensation, High Accuracy Ophthalmic Equipment

Place of Origin China
Brand Name KESHILONG
Certification CE
Model Number GD9401A
Minimum Order Quantity 1pcs
Price Negoatiable
Delivery Time 10-20 work days
Payment Terms L/C, T/T, Western Union
Supply Ability 150pcs/mont
Product Details
Measurement Mode Binocular Automatic/Monocular Automatic/Manual Measurement Range 1-60mmHg
Range 30mmHg/60mmHg Working Distance 11mm
Measurement Accuracy 0.1mmHg Measurement Light Source Measurement Light Source: 940nm LED
Screen Size 10.1inches Screen Rotation Range 360°flip Screen
Fixed View Light Type Green LED Work Movement X: ± 42.5mm, Y: ± 17mm, Z: ± 18mm
Leave a Message
Product Description

Automatic Non-Contact Tonometer NCT GD9401A

Features:

  1. Unique three-time weighted average algorithm that prompts the measurement results with low confidence based on the waveform quality.
  2. High-precision intraocular pressure value and an air jet control algorithm that delivers a soft and comfortable jet to the cornea.
  3. Advanced mute technology that reduces the noise and anxiety of the patients during the measurement. Simple and easy-to-use operation interface, automatic alarm prompt, and limit lock function that prevent the air jet from colliding with the eyeball, increasing safety and convenience.
  4. Corneal thick ness compensation is a function that adjusts the intraocu lar pressure measurement for patients with abnormal corneal thickness, improving accuracy.

 Automatic Non-Contact Tonometer NCT-NT-800, Digital Intraocular Pressure (IOP) Measurement, Pachymetry Compensation, High Accuracy Ophthalmic Equipment                           Automatic Non-Contact Tonometer NCT-NT-800, Digital Intraocular Pressure (IOP) Measurement, Pachymetry Compensation, High Accuracy Ophthalmic Equipment

                     Thorough Statistics                                                                        Case Information Module

It records the customer measurement data in detail                      Convenient and quick customer information records


 Automatic Non-Contact Tonometer NCT-NT-800, Digital Intraocular Pressure (IOP) Measurement, Pachymetry Compensation, High Accuracy Ophthalmic Equipment                            Automatic Non-Contact Tonometer NCT-NT-800, Digital Intraocular Pressure (IOP) Measurement, Pachymetry Compensation, High Accuracy Ophthalmic Equipment 

        Multiple Measurement Data Plotting                                                      On-key Operation Function

Convenient for customers to visually check changes                       Fully automatic binocular intraocular pressure

in intraocular pressure                                                                      measurement


Specification:

Automatic Non-Contact Tonometer NCT-NT-800, Digital Intraocular Pressure (IOP) Measurement, Pachymetry Compensation, High Accuracy Ophthalmic Equipment

 

Product & Service


Products:

  • Ophthalmic Instruments: Auto Refractometer, Phoropter, Auto Projector, PD Meter, Trial Lens Set, LCD Vision Chart, Ophthalmic Unit, Ophthalmic Motorized Table, Ophthalmoscope, Retinoscope etc;
  • Lens Testing Device: Auto Lensmeter, UV Tester, Blue Blocking Lens Tester, Stress Tester etc;
  • Lens Lab Instruments: Auto Lens Edger, Hand Lens Edger, Groover, Lens Driller, Ultrasonic Cleaner, Frame Warmer, Pliers & Screwdrivers etc;
  • Accessories: Lens Blocking Pads, Interliner etc.

Trade Conditions:

  • Payment: TT, Western Union, L/C, Paypal;
  • Lead Time: 7 - 14 working days to finish order;
  • Warranty: 1 Year;
  • Standard: ISO, CE, FDA
  • After Sale Service: Lifelong.

 About Us


Since from 2005, JingGong Optical started searching made in China optical instruments for optical wholesalers and chain stores, with many years’ experience and investment in this field, Now JingGong Optical is innovating, manufacturing & exporting a wide range of ophthalmic instruments, eyewear laboratory equipment, lab tools & accessories, if you are optical instruments wholesaler, optical shop, eye care hospital or lens laboratory, you can have best solutions from our instruments category.

In accordance with International & regional standards, JingGong Optical products are following ISO, CE & FDA instructions, also has warranty policy & maintenance service on each products, we are always working with customers to improve products and technology.

 

Our Vision: We are not going to save the world, we are not going to improve the eyesight of whole human being, but what we are concentrating on, is to provide our customers and end-users a precision, qualified, friendly-operated and lowest costed ophthalmology instruments and lens laboratory instruments.We are always hearing from our customers, to find every even small way to improve our products and service.

 

Guarantee:We absolutely understand you are worrying about the potential functional & quality problem of instruments you are buying from us, don’t worry, we carry out 100% QC before shipping, we also have guarantee for each product, buy from us means buy 100% satisfaction.

 

Staff:The employees who working for us, are with good background in optical industry, who was working in lens manufacturing, who was working in production line of eyewear, even has registered optometrist, our staff can think from different aspects instead of only one side.

Automatic Non-Contact Tonometer NCT-NT-800, Digital Intraocular Pressure (IOP) Measurement, Pachymetry Compensation, High Accuracy Ophthalmic Equipment